Power Adjustable Ultrasonic Cleaner
This medical ultrasonic cleaner instrument is a special ultrasonic cleaning equipment designed according to the hospital's special equipment cleaning requirements.
Product description:
One of the key features of this ultrasonic cleaner is its adaptability. Whether cleaning delicate jewelry or stubborn grease from industrial parts, the adjustable power setting ensures that the cleaning process is both gentle and effective. This not only preserves the integrity of the objects being cleaned but also extends the lifespan of the cleaning solution.
Moreover, the Power Adjustable Ultrasonic Cleaner boasts a compact design that makes it suitable for use in a wide range of settings, from commercial workshops to household kitchens. It is also equipped with user-friendly controls, allowing even those with limited technical knowledge to operate it with ease.
Specification:
|
Model |
Internal Dimensions (L*W*H) |
External Dimensions (L*W*H) |
Volume(L) |
Gross Weight(KG) |
Ultrasonic Power(W) |
Heating Powery(W) |
Drain valve |
Frequency(KHz) |
Time(Min) |
Heating Temperature(℃) |
|
UC-5120 |
240*135*100 |
268*170*290 |
3.2 |
6.7 |
120 |
100 |
yes |
40 |
1~99 |
1~80 |
|
UC-5120L |
240*135*150 |
268*170*290 |
5.0 |
7.2 |
120 |
200 |
yes |
|||
|
UC-5180 |
300*150*100 |
325*178*290 |
4.5 |
7.5 |
180 |
yes |
||||
|
UC-5180L |
300*150*150 |
325*178*290 |
6.8 |
7.7 |
180 |
200 |
yes |
|||
|
UC-5240L |
300*240*150 |
368*270*290 |
11 |
8.5 |
240 |
300 |
yes |
|||
|
UC-5360 |
330*300*150 |
397*335*317 |
15 |
11.5 |
360 |
400 |
yes |
|||
|
UC-5360L |
330*300*200 |
397*335*368 |
20 |
12.5 |
360 |
yes | ||||
|
UC-5480 |
500*300*150 |
560*320*317 |
22 |
14.5 |
480 |
500 |
yes |
|||
|
UC-5600 |
500*300*200 |
560*320*385 |
30 |
16.0 |
600 |
500 |
yes |

Power Adjustable Ultrasonic Cleaner is mainly composed of the following components:
1. Cleaning tank: holding the workpiece to be washed. Whcih is made of stainless steel, which can be equipped with heating and temperature control devices.
2. The ultrasonic transducer is bonded at the bottom of the cleaning tank. Piezoelectric ceramic transducer, frequency and power depending on the specific model.
3. Power supply: provide the required electric energy for the transducer. The inverter power supply, imported IGBT components, and installed overcurrent protection circuit.
FAQ:
Common faults and solutions of desktop Power Adjustable Ultrasonic Cleaner
Regular desktop ultrasonic cleaning machines have various types and different functions, but their common faults are similar. If users encounter some common faults in the process of use, they can solve them by themselves without hiring maintenance personnel. The following common faults and solutions of desktop ultrasonic cleaning machine are briefly described:
1, the water is too slow.
First, we should check whether the water inlet of the desktop ultrasonic cleaning machine is too slow due to the low water pressure, and check the water pressure gauge to find out the reason for the low water pressure. If this is not the reason, it is most likely because the inlet filter is blocked. At this time, the filter should be removed to clean up the impurities.
2. The heating rate is slow.
There may be two reasons here. The first one is that the heating pipe is out of phase or damaged. At this time, a new heating pipe needs to be replaced. The second possibility is that the temperature sensor of the desktop ultrasonic cleaning machine is damaged and needs to be corrected or replaced.
3. drainage time is too long.
The long drainage time is mainly caused by two reasons. The first drainage pump does not work. At this time, it is necessary to check whether the drainage pump is short-circuited and whether it is powered on. If the second drainage pipe is blocked, the connector of the drainage pipe should be removed to clean up the impurities inside.
4. The water pressure of medical flushing tank is too low.
Usually, this phenomenon is caused by either the reverse rotation of the circulating pump of the desktop ultrasonic cleaning machine or too little water in the tank. The corresponding solution is to reinstall the line switch or inject more water into the tank of the desktop ultrasonic cleaning machine.
5. The strength of ultrasonic cleaning machine is unstable.
If it can be that the inductance coil of the desktop ultrasonic cleaning machine is not firmly fixed, it needs to be fixed again. If not, it usually needs to readjust the matching of the inductance of the desktop ultrasonic cleaning machine.
6. The temperature display is quite different from the actual one.
Most of the reasons for this phenomenon are that the temperature sensor of the desktop ultrasonic cleaning machine is damaged or not connected properly. Either the sensor is replaced, or the sensor needs to be calibrated after adjusting the connector of the temperature sensor.
In fact, as long as the desktop ultrasonic cleaning machine is operated in strict accordance with the operation steps, it will generally not fail. However, if the above-mentioned glitches occur, users need not panic. They only need to make a simple judgment by using the above knowledge points. If they still can't be solved, they can find a trusted desktop ultrasonic cleaning machine repair company for on-site repair.
For more details of Power Adjustable Ultrasonic Cleaner, please feel free to contact us!