JYD-760E It is the use of full-bridge digital pulse drive. Compared to the half-bridge drive control circuit, ultrasonic transducer generator has the advantages of small size, simple peripheral circuits, stable ultrasonic effects, and high conversion efficiency.

Jyd-760e Ultrasonic generator adopts full bridge digital pulse drive. Compared with half bridge drive control circuit, ultrasonic transducer generator has the advantages of small volume, simple peripheral circuit, stable ultrasonic effect and high conversion efficiency. It has frequency tuning function to ensure that the machine is always in the best working state, and it can give full play to the potential of ultrasonic transducer, and it has perfect over-current protection and output short-circuit protection. It integrates the functions of digital ammeter, frequency and time control, PLC remote control, lamp pole indicating power supply and so on. On the basis of the above functions, there are new functions such as frequency locking, current locking, frequency sweep mode selection, automatic frequency tracking, 485 communication (optional) and one key degassing (optional) are added.

 

 

Specification of Ultrasonic Transducer Generator

Product model

JYD-761E

JYD-762E

JYD-763E

JYD-760EG

Driving power

600W-1500W

1500W-2100W

2100-2400W

600W-1500W

Power control

10-100%

10-100%

10-100%

10-100%

Working frequency

20KHz-40KHz

20KHz-40KHz

20KHz-40KHz

50KHZ-100KHZ

Working voltage

220V±10%

50Hz/60Hz

220V±10%

50Hz/60Hz

220V±10%

50Hz/60Hz

220V±10%

50Hz/60Hz

Maximum output current

5A

6A

7.5A

3.5A

Ambient temperature

0-40℃

0-40℃

0-40℃

0-40℃

Net weight of product

6.5KG

8.2KG

8.2KG

6.5KG

External dimensions

365*300*145mm

365*300*145mm

365*300*145mm

365*300*145mm

 

Ultrasonic Transducer Generator

 

The JYD-760E ultrasonic transducer generator's digital display buttom's function:

Name

Function specifications

Power switch

Power switch is general power switch for the whole machine, which is on and off when it is pushed and pressed respectively.

Indicator

It refers to state indicator for current operation of the generator. There are 5 indicators including current display, frequency display, time/PLC display, display of mode of sweep display and display of working state.

Operation key

The icon Mode button, in order to switch the LED digital display mode, can display the whole working current, ultrasonic working frequency, timing time/PLC, or sweep mode.

The icon ON/OFF button is the ultrasonic start/stop switch that can turn on or off the ultrasound.

Icon + button, you can add current or time, when the LED digital display for the current mode, ultrasonic work on, you can add current, this time the light bar will increase with the current increase, plus a current mode a total of 16 files; when the LED The digital display is time mode, which can increase the time of the ultrasonic work. The ultrasonic time is 0-59min59s.

The icon - button, you can reduce the current or time. When the LED digital display is in current mode, when the ultrasonic work is on, the current can be reduced. At this time, the light bar will decrease with the current, and the current reduction mode will decrease by 0.1A per time. When the LED digital display is in time mode, the ultrasonic operation timing can be reduced.

The icon AFT button can automatically track the frequency. When this button is pressed for 2 seconds, the ultrasonic cleaning generator enters the auto-frequency tuning mode.

 

Main features:

1. Working voltage: the power line of the ultrasonic generator is a standard three pin plug, and the AC voltage when powered on is 220V ± 10%. The power supply voltage needs to be stable.

2. Ultrasonic frequency: the output frequency of the ultrasonic generator needs to be within the frequency range of ± 1.5khz of the ultrasonic vibrator, and the adjustment of the offset frequency is prone to failure (vibrator damage or generator failure)

3. Power matching: the maximum driving power of the ultrasonic cleaner generator is close to the total power of the ultrasonic vibrator. For example, a 900W generator cannot drive a 2100W ultrasonic vibrator.

4. Working environment: the tail of the ultrasonic transducer generator is a cooling fan, and the right side is a cooling window. When using, it should be placed 15cm away from the tail and the right side, without obstacles. The environment should not be wet, the temperature should be appropriate, and the ventilation and heat dissipation should be good.

 

FAQ:

How do I match the ultrasonic transducer generator frequency to my cleaning application?

Use 20–28 kHz for heavy grease or carbon on robust metal parts like engine blocks.
Use 40 kHz for general industrial cleaning – it's our most popular frequency.
Use 50–100 kHz for delicate parts like electronics, optics, or medical instruments where you cannot risk surface damage.

Tell me your part and contaminant, and I can recommend the exact frequency.

 

Is your ultrasonic transducer generator compatible with my existing transducers or tank?

Usually yes, but compatibility depends on three key factors: frequency, impedance, and connector type.

If your existing transducers operate at the same frequency as our generator (for example, 40 kHz), and the impedance is within our auto-tuning range, it will very likely work.

The safest way? Send me a photo of your transducer nameplate or a quick spec sheet. I can confirm compatibility for you within one business day. No charge, no obligation.

 

What safety and protection features are included?

Our ultrasonic transducer generator is built with six layers of protection to prevent damage from electrical faults, overheating, or operator error:

Over-temperature protection (thermal shutdown)

Overload protection (current limiting)

Short circuit protection

Open circuit protection (safe operation if transducer disconnects)

Over-voltage protection

Soft start (prevents power surge on power-up)

These features are automatic – no user intervention required. If a fault occurs, the generator shuts down safely and shows an error code on the display."

 

 