How to solve the problem of ultrasonic vibrating screen cooling system failure?
Dec 15, 2022
Common faults have the following three phenomena:
1. Ultrasonic vibrator is damp.
2. Ignite of transducer vibrator and damage of ceramic material.
3. Degumming of vibrator
Workaround:
1. When the ultrasonic vibrator is damp, you can check the connecting plug of the ultrasound transducer with a megohmmeter. By checking the insulation resistance value, you can judge the basic situation. Generally, the insulation resistance is greater than 5 megohms. If the insulation resistance value cannot be reached, the whole transducer can be put into an oven and dried at about 100℃ for three hours or dehumidified with a hair dryer until the insulation resistance value is normal;
The ultrasonic sieve transducer is fastened by cement screws, and the ultrasonic screening transducer will be wet after 10 years of full load use.
2. Igniting phenomenon of ultrasonic sieving transducer vibrator can be checked by megohmmeter or naked eye, and disconnecting the damaged vibrator will not affect the normal use of other vibrators;
3. The debonding phenomenon of the vibrator is mostly due to the long service life of the transducer, so it can be used again after re-bonding.
The ultrasonic vibrating screen transducer doesn't have to have problems before it can be solved. In the process of use, we need to do a good job in daily maintenance.