Paper cup machine ultrasonic always burns thyristor. How to repair it?

Dec 02, 2022

If paper cup machine ultrasonic always burns thyristors, you should carefully check whether there is any problem with the ultra sound transducer and the beam. If there is no problem, you can repair it according to my method. If you still can't fix it, it is estimated that there is something wrong with the vibration board, which needs our professional repairman to pay for it.

1, replace the triode, try to make its parameters consistent with other triodes.

2. Check the transducer and amplitude transformer (that is, amplitude transformer) to see if they are damaged. See if there is any crack in the main metal block, and if there is any crack or dislocation in the piezoelectric ceramic sheet of the ultrasonic transducer.

3. Check whether the connection between the ultrasound transducer and the horn is tight. If it is loose, use tools to tighten it.

4. When testing ultrasound, be sure to connect the ultrasonic welding transducer with the ultrasonic horn, and no mold is required. When pressing the test switch, it should be released once, and the time should be controlled within 1 second. Observe the pointer range of amplitude meter, and then perform frequency modulation.