Ultrasonic hand-held welding machine maintenance method
Apr 27, 2022
How to maintain ultrasonic hand-held welding? There are generally the following methods:
1. Check and replace ultrasonic welding head regularly. Due to the larger aperture of the wear welding head, it will lead to arc instability, weld appearance deterioration or bonding (heat recovery); The end of the conductive mouth is stuck to the splash, and the wire is not smooth; The ultrasonic welding head is not tight, the thread connection will heat up and die.
2. Clean and replace the spring hose regularly
After a long time of use, the spring hose will accumulate a lot of iron powder, dust, wire plating chips, etc., which will make the wire delivery unstable, so it is important to clean regularly. It can be curled and gently tapped to shake off the accumulation and then blown off with compressed air. The grease on the hose should be washed in oil with a brush, and then blown clean with compressed air. If the spring hose is miswired or severely deformed, it should be replaced with a new hose. When changing tubes, make sure it is suitable for the diameter and length of the welding wire used, and there is no burr on the cutting surface.
3. Check the insulation ring
If the insulating ring is removed for welding, the splash will adhere to the nozzle, causing the nozzle to connect to the live part. The spot torch may burn out due to a short circuit. At the same time, insulation rings must be installed to protect even outflow of gas.
Of course, the use of welding equipment for a long time, there will naturally be equipment damage, do a good job of machine maintenance, can reduce some failures, prolong the working time, in order to save costs.